User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 516 System Manual
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the avgduration-cinr parameter to
the default value, run the following command:
npu(config-bs-66053)# no triggersetup avgduration-cinr
This parameter will be restored to its default value, while the other parameters
will remain unchanged.
To restore all Trigger Setup parameters to their default value, run the following
command:
npu(config-bs-66053)# no triggersetup
3.8.10.3 Displaying Configuration Information for Trigger Setup
Parameters
To display configuration information for Trigger Setup parameters, run the
following command:
npu# show triggersetup bs [<(1 to 16777215 StepSize 1)
Specify the BS ID if you want to display configuration for a particular BS. For
example, to display the Trigger Setup parameters of BS 66053, run the following
command:
npu# show triggersetup bs 66053
Do not specify this parameter if you want to view configuration information for all
existing BSs. To display information for all BSs, run the following command:
npu# show triggersetup bs
NOTE
Refer to Section 3.8.10.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no triggersetup [avgduration-rssi]
[avgduration-cinr] [avgduration-rtd ]
Privilege
Level
10
Command
Modes
bs configuration mode