User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 621 System Manual
Do not specify this parameter if you want to view configuration information for all
existing BSs. To display information for all BSs, run the following command:
npu# show ranging-general bs
3.8.24 Managing Alarm Threshold Parameters
After enabling the BS configuration mode, you can execute the following tasks:
Command
Syntax
npu# show ranging-general bs [<(1 to 16777215 StepSize 1)
Privilege
Level
1
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
The BS ID
Specify a value for this
parameter if you want to
display the Ranging General
parameters of a specific BS.
Do not specify a value for this
parameter if you want to
display the Ranging General
parameters of all BSs.
Optional N/A 1-16777215
Display
Format
(for each
existing BS
if requested
for all BSs)
BSIDLSB :<value>
StartofRangingCodes :<value>
MaximumCellRadius(km) :<value>
Command
Modes
Global command mode