User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 624 System Manual
3.8.24.2 Restoring the Default Values of Alarm Threshold Parametes
To restore the default values of some or all of the Alarm Threshold parameters,
run the following command:
npu(config-bs-66053)# no alrm-thrshld [ul-mednoise] [ul-99prcntnoise]
[Be-exc-dl-drop-thr ] [rt-exc-dl-drop-thr ] [nrt-exc-dl-drop-thr ]
[ugs-exc-dl-drop-thr ] [ert-exc-dl-drop-thr ]
You can restore only some parameters to the default values by specifying only
those parameter. For example, to restore only the ul-mednoise parameter to the
default value, run the following command:
npu(config-bs-66053)# no alrm-thrshld ul-mednoise
This parameter will be restored to its default value, while the other parameters
will remain unchanged.
To restore all Alarm Threshold parameters to their default value, run the following
command:
npu(config-bs-66053)# no alrm-thrshld
[nrt-exc-dl-dr
op-thr <(1 to
1000 StepSize
1)> ]
Threshold for Excessive
DL Dropped Packets
Ratio for Non Real Time(in
promils)
Optional 1000 1 - 1000
[ugs-exc-dl-dr
op-thr <(1 to
1000 StepSize
1)> ]
Threshold for Excessive
DL Dropped Packets
Ratio for UGS(in promils)
Optional 1000 1 - 1000
[ert-exc-dl-dr
op-thr <(1 to
1000 StepSize
1)> ]
Threshold for Excessive
DL Dropped Packets
Ratio for ERT(in promils)
Optional 1000 1 - 1000
Command
Modes
bs configuration mode
NOTE
Refer to Section 3.8.24.1 for a description and default values of these parameters.