User's Manual

Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 405 System Manual
3.3.15.5.2 Clearing Dry-contact Output Alarms
After the system returns to its normal state, run the following command to clear
the dry-contact output alarm that you had raised:
npu(config)# no dry-contact OUT <alarm_num (1-3)>
After you run this command, the alarm that you had raised is cleared.
alarm <alarm
name>
Indicates the name of the
dry-contact alarm to be
raised.
Mandatory N/A Up to 256
characters
Command
Modes
Global configuration mode
NOTENOTE
For more information about raising a dry contact ouput alarm, refer to
“Raising Dry-contact
Output Alarms” on page 403
.
Command
Syntax
npu(config)# no dry-contact OUT <alarm_num (1-3)>
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<alarm_num
(1-3)>
Indicates the alarm number of
the dry contact output alarm
alarm that is to be disabled.
For more information about
the pin numbers that
correspond to the alarm
number, refer
Table 3-29.
Mandatory N/A 1-3
Command
Modes
Global configuration mode