User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing ODUs
4Motion 438 System Manual
After executing the above tasks, you can terminate the ODU Port configuration
mode (refer to Section 3.6.2.4) and return to the global configuration mode.
3.6.2.2 Configuring ODU Port Parameters
After enabling the ODU Port configuration mode you can configure the transmit
power parameters of the port.
Command
Syntax
npu (config)# odu-port <(1 to 28 StepSize 1)> <(1 to 4 StepSize 1)> [txpower <(0 to 46 StepSize
0.1)>]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 28 StepSize 1)> The ODU number Mandatory N/A 1-28
<(1 to 4 StepSize 1)> The Port number. Mandatory N/A 1-4
[txpower <(0 to 46
StepSize 0.1)>]
The required tx power at the
specified ODU Port, in dBm.
The actually available range
depends on ODU Type: The
upper limit is set by the
Maximum Tx Power supported
by the ODU . The control range
for all ODUs is 10dBm, except
to the following ODUs whose
control range is 6dBm:
oDU23002360000N361by1N0,
oDU23402400000N361by1N0,
oDU24962602000N361by1N0,
oDU25902690000N361by1N0,
oDU23052360000N361by1Y0
Mandatory
for a new
ODU Port
N/A 0 to 46 in
increment
s of 0.1
Command
Modes
Global configuration mode
NOTE
The following examples are for odu-1, port-1 configuration mode.