User's Manual

Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 104 System Manual
1 Enable the interface configuration mode (refer Section 3.3.2.3.1).
2 You can now enable any of the following tasks:
» Modify the physical properties of an interface (refer Section 3.3.2.1.2).
» Manage VLAN translation (refer Section 3.3.2.1.3).
3 Terminate the interface configuration mode (refer Section 3.3.2.3.7).
You can, at any time, display VLAN membership information (refer
Section 3.3.2.1.5), and VLAN translation entries for the DATA port (refer
Section 3.3.2.1.7).
3.3.2.1.1 Enabling the Interface configuration mode
To configure a physical interface, run the following command to enable the
interface configuration mode.
npu(config)# interface {<interface-type> <interface-id>
|internal-mgmt |external-mgmt | bearer | local-mgmt | npu-host |
all-au}
Table 3-11: Ethernet Interfaces - Types, Port Numbers, and Member VLANs
Interface Type Physical Interfaces Port
Number
Member VLANs
Fast Ethernet MGMT 0/8
Local-management (in
the in-band or unified
connectivity modes)
External-management
(only in the out-of-band
connectivity mode)
Gigabit Ethernet CSCD 0/9
Local-management
DATA 0/10
Bearer·
External-management
(only in-band
connectivity mode)
Multiple Service VLAN
AU maintenance
To configure a physical interface: