74 Commissioning
Chapter 3 - Commissioning
3.1 Configuring Basic Parameters of Base
Station
3.1.1 NPU Parameters Required for Management
After completing the installation process, as described in the preceding chapter,
some basic NPU parameters must be configured using the Monitor application via
the MON port of the NPU. These parameters are necessary to enable remote
management using SNMP or Telnet.
If the NPU is in the default factory configuration, or if the IP parameters of either
the Data or Management port are known, you may configure the parameters using
Telnet. You may also use AlvariCRAFT, provided you know the IP parameters of
one port and the Authorized Managers list in the NPU is either empty (default) or
includes the IP address of the AlvariCRAFT station.
Refer to Chapter 4 for information on how to access the Monitor application either
via the MON port or via Telnet and how to use it.
Refer to the AlvariCRAFT User Manual for information on how to use it.
The basic parameters are listed in Table 3-1. Refer to Chapter 4 for detailed
information on the applicable parameters.
NOTE
The default Installer password is "installer".
Table 3-1: Basic NPU Parameters
Management Option Parameters
MGMT port
Management Port IP address
Management Port Subnet Mask
Management Port Gateway
Management Port Destination Subnet
Management Port Destination Subnet Mask
Management Port Management Traffic Enable/Disable