User's Manual
Table Of Contents
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - System Description
- 1.1 Introducing BreezeMAX
- 1.2 Base Station Equipment
- 1.3 Networking Equipment
- 1.4 Management Systems
- 1.5 Specifications
- 1.5.1 Radio
- 1.5.2 Base Station 2.X GHz Antennas (Optional)
- 1.5.3 Base Station 3.x GHz Antennas (Optional)
- 1.5.4 ˘AU-IDU to AU-ODU Communication
- 1.5.5 Data Communication (Ethernet Ports)
- 1.5.6 Configuration and Management
- 1.5.7 Environmental
- 1.5.8 Standards Compliance, General
- 1.5.9 Services
- 1.5.10 Physical and Electrical
- Chapter 2 - Installation Guidelines
- 2.1 Installing the AU-ODU
- 2.2 Installing the Base Station Equipment
- 2.2.1 BST Installation Requirements
- 2.2.2 BMAX-BST-SH Chassis Slot Assignments
- 2.2.3 Power Requirements
- 2.2.4 HOT SWAP Support
- 2.2.5 Power Interface Unit (PIU)
- 2.2.6 Power Supply Unit (PSU)
- 2.2.7 Access Unit Indoor Module (AU-IDU)
- 2.2.8 Network Processing Unit (NPU)
- 2.2.9 Using the Hot Swap Injector/Ejector Handles
- 2.2.10 Installing the Base Station Chassis and Modules
- 2.2.11 Air Ventilation Unit (AVU)
- 2.2.12 Replacing Base Station Components
- 2.3 Installing the ODU Power Feeder
- 2.4 Installing the GPS Adapter
- Chapter 3 - Commissioning
- Chapter 4 - Operation and Administration
- 4.1 BreezeMAX System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 ˘The NPU's Main Menu
- 4.5 Base Station Menu
- 4.5.1 Show
- 4.5.2 Configuration
- 4.5.3 Alarms and Traps
- 4.5.4 RADIUS
- 4.5.5 ˘˘˘Licenses
- 4.6 ˘NPU Menu
- 4.7 Radio Cluster Menu
- 4.8 ODU Menu
- 4.9 AU Menu
- 4.9.1 Show Summary
- 4.9.2 Upgrading AU’s SW
- 4.9.3 SW Files in NPU
- 4.9.4 Select
- 4.9.5 AU Slot # Menu
- 4.9.6 Performance Monitoring
- 4.10 SU Menu
- 4.10.1 Show Summary
- 4.10.2 Show Summary by AU
- 4.10.3 Upgrading SU’s SW
- 4.10.4 ˘SW Files in NPU
- 4.10.5 Select by Name
- 4.10.6 Select by MAC Address
- 4.10.7 SU # Menu
- 4.10.7.1 Show
- 4.10.7.2 Unit Control
- 4.10.7.3 Configuration
- 4.10.7.3.1 Registration Parameters
- 4.10.7.3.2 MAC (Standard FDD) Parameters
- 4.10.7.3.3 Phy (Standard FDD) Parameters
- 4.10.7.3.4 Multirate and ATPC Parameters
- 4.10.7.3.5 Voice/Networking Gateways
- 4.10.7.3.6 Ethernet Port
- 4.10.7.3.7 Installer Password
- 4.10.7.3.8 ˘Bridging Parameters
- 4.10.7.3.9 License
- 4.10.7.3.10 Best BST/AU (Advanced Si)
- 4.10.7.3.11 Radio Parameters (Advanced Si)
- 4.10.7.4 Performance Monitoring
- 4.10.7.5 Show MAC Addresses Behind SU
- 4.10.7.6 Delete
- 4.10.8 Add New SU
- 4.10.9 Clear All Configured SU SW Files
- 4.11 Services Menu
- 4.11.1 Introduction to Services
- 4.11.2 Introduction to Filtering Features
- 4.11.3 Common Operations in Services Menu
- 4.11.4 The Services Menu
- 4.11.4.1 General
- 4.11.4.2 Subscribers
- 4.11.4.3 Services
- 4.11.4.4 Service Profiles
- 4.11.4.4.1 Service Profile Name
- 4.11.4.4.2 Service Type
- 4.11.4.4.3 VLAN Transparency Mode
- 4.11.4.4.4 VPL ID
- 4.11.4.4.5 Priority Marking Mode
- 4.11.4.4.6 Priority Marking Value
- 4.11.4.4.7 Forwarding Rule
- 4.11.4.4.8 Priority Classifier (L2 and PPPoE Service Type)
- 4.11.4.4.9 Maximum Number of Voice Calls (L2 and VoIP Service Type)
- 4.11.4.4.10 Service Profile Class
- 4.11.4.5 Forwarding Rules
- 4.11.4.6 Priority Classifiers
- 4.11.4.7 QoS Profiles
- 4.11.4.8 Filtering Rules
- 4.11.4.9 Interface Filtering
- 4.11.4.10 Filtering Examples
- 4.11.4.11 MAC Addresses Deny List
- 4.11.5 Defining Service Profiles
- 4.11.6 Defining Local (Permanent) Services
- 4.11.7 Defining RADIUS Based Services
- 4.11.8 Pre-configured Profiles
- 4.12 NPU Parameters Summary
- Appendix A - Software Upgrade
- Appendix B - Defining Service Profiles for Generic VoIP Gateways
- Glossary
- Index
NPU Menu
BreezeMAX Modular Base Station System Manual 127
Shadow SW File
Shadow SW Version
Running From: The currently running version (Main or Shadow)
Boot SW Version
Frequency Bands File Version
4.6.2 Unit Control
The Unit Control menu of the NPU enables changing the access Passwords and
the Monitor Inactivity Timeout, resetting the NPU, reverting the Base Station and
the NPU to the factory default configuration, managing the SW versions of the
module and creating backup files.
The Unit Control menu includes the following options:
Change Password
Reset
Set Factory Defaults
SW Versions Control
Create Backup
Monitor Inactivity Timeout
4.6.2.1 Change Password
For security and control reasons, the Change Password option is available only for
users with Administration access rights. The Change Password option enables
defining the passwords for each of the three different access levels: Administrator,
Installer and Monitor. After changing the password for a selected access level, you
will be prompted to re-enter the new password for confirmation.
Valid passwords: Up to 16 printable characters, case sensitive.
NOTE
For security reasons, the passwords do not change after performing the Set Factory Defaults
operation. For the same reason, the passwords cannot be managed using SNMP and are are not
included in backup configuration files.