B The local subnet of the Data port (defined by the Data Port IP Address and
Data Port Subnet Mask parameters).
C Any subnet reachable via the Gateway of the Management port (if defined).
Note that in this case the Static Route (if defined) is ignored, and the defined
Gateway becomes the default Gateway, enabling remote management by any
PC reachable via the Gateway.
If remote management is enabled for both the Data Port and the Management
port, then the unit can be managed by any PC on any of the following subnets
(provided the PC is defined as an Authorized Manager):
A The local subnet of the Management port (defined by the Management Port IP
Address and Management Port Subnet Mask parameters).
B The local subnet of the Data port (defined by the Data Port IP Address and
Data Port Subnet Mask parameters).
C Any subnet reachable via the default Gateway of the Data port (if Data Port
Gateway is defined).
D The remote Static Route subnet (defined by the Management Port Dest Subnet
and Management Port Dest Subnet Mask parameters) reachable via the
Gateway of the Management port.
4.6.3.3 Authorized Managers
The Authorized Managers submenu enables defining the properties of
management stations that are allowed to manage the Base Station using SNMP,
including all its components and the SUs associated with it.
The Authorized Manager submenu includes the following options:
NOTE
To prevent the undesired situation where remote management traffic is unintentionally disabled in
both the Management and Data ports, the Management Port Management Traffic Enable/Disable
parameter will be automatically forced to Enabled upon disabling the Data Port Management
Traffic, and vice versa.
The Data Port Management Traffic Enable/Disable parameter is available only in the Monitor
program. It is not available when using SNMP.
NOTE
If no Authorized Manager is defined in the device, it can be managed using SNMP by any station,
with the default Read (public) and Write (private) Communities. If at least one Authorized Manager
is defined, the device can be managed only by a station whose parameters match a defined
Authorized Manager.