User's Manual
Table Of Contents
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - System Description
- 1.1 Introducing BreezeMAX
- 1.2 Base Station Equipment
- 1.3 Networking Equipment
- 1.4 Management Systems
- 1.5 Specifications
- 1.5.1 Radio
- 1.5.2 Base Station 2.X GHz Antennas (Optional)
- 1.5.3 Base Station 3.x GHz Antennas (Optional)
- 1.5.4 ˘AU-IDU to AU-ODU Communication
- 1.5.5 Data Communication (Ethernet Ports)
- 1.5.6 Configuration and Management
- 1.5.7 Environmental
- 1.5.8 Standards Compliance, General
- 1.5.9 Services
- 1.5.10 Physical and Electrical
- Chapter 2 - Installation Guidelines
- 2.1 Installing the AU-ODU
- 2.2 Installing the Base Station Equipment
- 2.2.1 BST Installation Requirements
- 2.2.2 BMAX-BST-SH Chassis Slot Assignments
- 2.2.3 Power Requirements
- 2.2.4 HOT SWAP Support
- 2.2.5 Power Interface Unit (PIU)
- 2.2.6 Power Supply Unit (PSU)
- 2.2.7 Access Unit Indoor Module (AU-IDU)
- 2.2.8 Network Processing Unit (NPU)
- 2.2.9 Using the Hot Swap Injector/Ejector Handles
- 2.2.10 Installing the Base Station Chassis and Modules
- 2.2.11 Air Ventilation Unit (AVU)
- 2.2.12 Replacing Base Station Components
- 2.3 Installing the ODU Power Feeder
- 2.4 Installing the GPS Adapter
- Chapter 3 - Commissioning
- Chapter 4 - Operation and Administration
- 4.1 BreezeMAX System Management
- 4.2 The Monitor Program
- 4.3 IP Addresses Configuration
- 4.4 ˘The NPU's Main Menu
- 4.5 Base Station Menu
- 4.5.1 Show
- 4.5.2 Configuration
- 4.5.3 Alarms and Traps
- 4.5.4 RADIUS
- 4.5.5 ˘˘˘Licenses
- 4.6 ˘NPU Menu
- 4.7 Radio Cluster Menu
- 4.8 ODU Menu
- 4.9 AU Menu
- 4.9.1 Show Summary
- 4.9.2 Upgrading AU’s SW
- 4.9.3 SW Files in NPU
- 4.9.4 Select
- 4.9.5 AU Slot # Menu
- 4.9.6 Performance Monitoring
- 4.10 SU Menu
- 4.10.1 Show Summary
- 4.10.2 Show Summary by AU
- 4.10.3 Upgrading SU’s SW
- 4.10.4 ˘SW Files in NPU
- 4.10.5 Select by Name
- 4.10.6 Select by MAC Address
- 4.10.7 SU # Menu
- 4.10.7.1 Show
- 4.10.7.2 Unit Control
- 4.10.7.3 Configuration
- 4.10.7.3.1 Registration Parameters
- 4.10.7.3.2 MAC (Standard FDD) Parameters
- 4.10.7.3.3 Phy (Standard FDD) Parameters
- 4.10.7.3.4 Multirate and ATPC Parameters
- 4.10.7.3.5 Voice/Networking Gateways
- 4.10.7.3.6 Ethernet Port
- 4.10.7.3.7 Installer Password
- 4.10.7.3.8 ˘Bridging Parameters
- 4.10.7.3.9 License
- 4.10.7.3.10 Best BST/AU (Advanced Si)
- 4.10.7.3.11 Radio Parameters (Advanced Si)
- 4.10.7.4 Performance Monitoring
- 4.10.7.5 Show MAC Addresses Behind SU
- 4.10.7.6 Delete
- 4.10.8 Add New SU
- 4.10.9 Clear All Configured SU SW Files
- 4.11 Services Menu
- 4.11.1 Introduction to Services
- 4.11.2 Introduction to Filtering Features
- 4.11.3 Common Operations in Services Menu
- 4.11.4 The Services Menu
- 4.11.4.1 General
- 4.11.4.2 Subscribers
- 4.11.4.3 Services
- 4.11.4.4 Service Profiles
- 4.11.4.4.1 Service Profile Name
- 4.11.4.4.2 Service Type
- 4.11.4.4.3 VLAN Transparency Mode
- 4.11.4.4.4 VPL ID
- 4.11.4.4.5 Priority Marking Mode
- 4.11.4.4.6 Priority Marking Value
- 4.11.4.4.7 Forwarding Rule
- 4.11.4.4.8 Priority Classifier (L2 and PPPoE Service Type)
- 4.11.4.4.9 Maximum Number of Voice Calls (L2 and VoIP Service Type)
- 4.11.4.4.10 Service Profile Class
- 4.11.4.5 Forwarding Rules
- 4.11.4.6 Priority Classifiers
- 4.11.4.7 QoS Profiles
- 4.11.4.8 Filtering Rules
- 4.11.4.9 Interface Filtering
- 4.11.4.10 Filtering Examples
- 4.11.4.11 MAC Addresses Deny List
- 4.11.5 Defining Service Profiles
- 4.11.6 Defining Local (Permanent) Services
- 4.11.7 Defining RADIUS Based Services
- 4.11.8 Pre-configured Profiles
- 4.12 NPU Parameters Summary
- Appendix A - Software Upgrade
- Appendix B - Defining Service Profiles for Generic VoIP Gateways
- Glossary
- Index
NPU Menu
BreezeMAX Modular Base Station System Manual 137
B The local subnet of the Data port (defined by the Data Port IP Address and
Data Port Subnet Mask parameters).
C Any subnet reachable via the Gateway of the Management port (if defined).
Note that in this case the Static Route (if defined) is ignored, and the defined
Gateway becomes the default Gateway, enabling remote management by any
PC reachable via the Gateway.
If remote management is enabled for both the Data Port and the Management
port, then the unit can be managed by any PC on any of the following subnets
(provided the PC is defined as an Authorized Manager):
A The local subnet of the Management port (defined by the Management Port IP
Address and Management Port Subnet Mask parameters).
B The local subnet of the Data port (defined by the Data Port IP Address and
Data Port Subnet Mask parameters).
C Any subnet reachable via the default Gateway of the Data port (if Data Port
Gateway is defined).
D The remote Static Route subnet (defined by the Management Port Dest Subnet
and Management Port Dest Subnet Mask parameters) reachable via the
Gateway of the Management port.
4.6.3.3 Authorized Managers
The Authorized Managers submenu enables defining the properties of
management stations that are allowed to manage the Base Station using SNMP,
including all its components and the SUs associated with it.
The Authorized Manager submenu includes the following options:
NOTE
To prevent the undesired situation where remote management traffic is unintentionally disabled in
both the Management and Data ports, the Management Port Management Traffic Enable/Disable
parameter will be automatically forced to Enabled upon disabling the Data Port Management
Traffic, and vice versa.
The Data Port Management Traffic Enable/Disable parameter is available only in the Monitor
program. It is not available when using SNMP.
NOTE
If no Authorized Manager is defined in the device, it can be managed using SNMP by any station,
with the default Read (public) and Write (private) Communities. If at least one Authorized Manager
is defined, the device can be managed only by a station whose parameters match a defined
Authorized Manager.