User's Manual

Table Of Contents
148 Operation
Chapter 4 - Operation and Administration
Max Tx Power: The maximum Tx Power supported by the ODU. This read-only
parameter sets the upper limit for the Tx Power parameter (applicable only for
an associated ODU).
Actual Tx Power: The actual Tx power, that may differ from the Configured Tx
Power: If the configured value is below the minimum supported by the ODU
the actual power will be set to the minimum supported by the unit. If the
configured value is above the maximum supported by the ODU, the power will
be changed to the maximum value supported by the unit (applicable only for
an associated ODU).
4.8.2.2 Update
Select this option to update one or more of the selected ODU's parameters.
For details on the configurable parameters refer to Section 4.8.4.
4.8.2.3 Delete
Select this option to delete the selected ODU from the database.
4.8.3 Add
Select this option to define a new ODU.
For details on the configurable parameters refer to Section 4.8.4.
4.8.4 ODU Parameters
4.8.4.1 ODU ID
A number used to identify the ODU. The ODU ID is configurable only when adding
a new ODU.
The available values range from 1 to 24.
4.8.4.2 Associated Radio Cluster
The ID of the associated Radio Cluster.
The available values range from 1 to 6. The value must be that of an already
defined Radio Cluster.
4.8.4.3 Configured ODU Frequency Band
The Configured ODU Frequency Band will be modified through the use of
Frequency Bands Configuration file (see Section 4.8.5).