SU Menu
BreezeMAX Modular Base Station System Manual 195
End Downlink (Rx) Frequency (MHz)
Scanning Main Step
Scanning Intermediate Steps (Configured)
Scanning Intermediate Steps (Actual)
4.10.7.3.11.2.2Update
The Update menu enables configuration of the following parameters (changes in
Frequency Scanning parameters take effect only after reset):
Start Downlink (Rx) Frequency (MHz): The lowest frequency in the range of
frequencies to be scanned. The available values depend on the frequency range
defined by the Frequency Bands belonging to the applicable Frequency Bands
Group (see Section 4.8.5), and the configured Bandwidth.
End Downlink (Rx) Frequency (MHz): The highest frequency in the range of
frequencies to be scanned. The available values depend on the frequency range
defined by the Frequency Bands belonging to the applicable Frequency Bands
Group (see Section 4.8.5), and the configured Bandwidth.
Scanning Main Step (KHz): The Main Scanning Step, used to define the set of
“Main Frequencies” as described above.
For a Bandwidth of 3.5 MHz, the range is from 125 KHz to 1750 KHz, in steps
of 125 KHz.
For a Bandwidth of 5 MHz, the range is from 125 KHz to 5000 KHz, in steps of
125 KHz.
Scanning Intermediate Steps: The Intermediate Scanning Steps includes up
to 8 entries of numbers between 1 to 8, or 0 for none, that define the
intermediate frequencies to be scanned, as described above.
The highest step (in KHz) defined by the Intermediate Scanning Steps must be
smaller than the Scanning Main Step.