4.12 NPU Parameters Summary
Table 4-23: NPU Monitor Parameters Summary
Parameter Range Default Run-Time
Updated
Base Station Configuration Parameters
Device Name Up to 255 printable characters Null Yes
Device Location Up to 255 printable characters Null Yes
Switching Mode 1 - Ethernet CS
2 - IP CS
Ethernet CS No
ATPC Enable/Disable 1 - Disable
2 - Enable
Disable is temporary until next reset of the
NPU or AUs
Enable Yes
Optimal Uplink RSSI (dBm) -90 to -60 (-80 to -74 at the AUs) -73
(-74 at the AUs)
Yes
Operator ID X.X.X
X: 0-255
186.190.0 No
Cell ID X.X
X: 0-255
0.250 No
Duplex Mode FDD, TDD
Only TDD spplicable to current version)
TDD No
DL-UL Ratio 1: 65-35 (%)
2: 60-40 (%)
3: 55-45 (%)
4: 50-50 (%)
5: 45-55 (%)
6: 40-60 (%)
7: 35-65 (%)
(See Section 4.5.2.6.2 for limitations)
50-50 (%) No
External 1PPS Clock 1 - Disable
2 - Enable
Enable No