4Motion - DN1031 24
4Motion Configuration Using AlvariSTAR 4Motion Configuration
Parameter Name Value
Central frequency 2600.0
3.2.14.1.1.2 Air Frame Structure General
Configure the parameters according to Table 12.
Figure 22: RC AFSG
NOTE
Preamble Index formula: segment X 32 + Cell ID
Segment- available values: 0-2
Cell ID- available values: 0-31
Please notice that if the value of Preamble Index = 0, It means that this AU is down.
Table 12: RC AFSG
Parameter Name Value
Cell ID 31
Preamble group 1
Segment number 2
Preamble index 2*32+31 = 95
Frame number offset 0
Total uplink duration 6