User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 733 System Manual
4.8.28.2.4 Configuring Initial Ranging Parameters
To configure the Initial Ranging parameters, run the following command:
npu(config-bs-66053-ranging)# initrng [codes <(0 to 255 StepSize 1)>]
[init-backoff-window-size <(0 to 15 StepSize 1)>] [final-backoff-window-size <(0 to
15 StepSize 1)>]
init-backoff-window
-size <(0 to 15
StepSize 1)>
Initial backoff window size for
handover ranging contention ;
expressed as a power of 2.
Optional 0 0 - 15
final-backoff-windo
w-size <(0 to 15
StepSize 1)>
Final backoff window size for
handover ranging contention;
expressed as a power of 2.
Cannot higher than or equal to
horng init-backoff-window-size.
Optional 4 0 - 15
Command
Modes
bs ranging configuration mode
IMPORTANT
When creating a new BS, at least one of the Initial Ranging parameters must be configured
explicitly (even if configured to the default value).
Command
Syntax
npu(config-bs-66053-ranging)# initrng [codes <(0 to 255 StepSize 1)> ]
[init-backoff-window-size <(0 to 15 StepSize 1)> ]
[final-backoff-window-size <(0 to 15 StepSize 1)> ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values