User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 736 System Manual
4.8.28.3 Restoring Default Values for Ranging Configuration
Parameters
After enabling the Ranging configuration mode you can restore the default values
for parameters in the following parameters tables:
General (refer to Section 4.8.28.3.1)
Bandwidth Request (refer to Section 4.8.28.3.2)
Handover Ranging (refer to Section 4.8.28.3.3)
Initial Ranging (refer to Section 4.8.28.3.4)
Periodic Ranging (refer to Section 4.8.28.3.5)
Timing Correction (refer to Section 4.8.28.3.6)
4.8.28.3.1 Restoring the Default Values of Ranging General Parameters
To restore one or all of the Ranging General parameters to their default values,
run the following command:
npu(config-bs-66053-ranging)# no general [start-of-rng-codes]
[contbased-rsrvtimeout] [max-cellradius]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only max-cellradius to the default
value, run the following command:
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
thrshld-correction
<(0 to 250
StepSize 0.1)>
Timing correction range threshold (in
microseconds) below which
corrections aren't made.
Optional 1 0 - 250 in
steps of
0.1
thrshld-rngstatus
<(0 to 250
StepSize 0.1)>
Timing correction range threshold (in
microseconds) below which the
ranging status is success and above
which the ranging status is continue
Optional 10 0 - 250 in
steps of
0.1
Command
Modes
bs ranging configuration mode