User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 747 System Manual
4.8.28.5.5 Displaying Configuration Information for Periodic Ranging Parameters
To display configuration for the Periodic Ranging parameters, run the following
command:
npu# show ranging-periodicrng bs [<(1 to 16777215 StepSize 1)
Specify the BS ID if you want to display configuration for a particular BS. For
example, to display the Periodic Ranging parameters of BS 66053, run the
following command:
npu# show ranging-periodicrng bs 66053
Do not specify this parameter if you want to view configuration information for all
existing BSs. To display information for all BSs, run the following command:
npu# show ranging-periodicrng bs
Command
Syntax
npu# show ranging-periodicrng bs [<(1 to 16777215 StepSize 1)
Privilege
Level
1
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
The BS ID
Specify a value for this
parameter if you want to
display the Periodic Ranging
parameters of a specific BS.
Do not specify a value for this
parameter if you want to
display the Periodic Ranging
parameters of all BSs.
Optional N/A 1-16777215
Display
Format
(for each
existing BS
if requested
for all BSs)
BSIDLSB :<value>
NumberofPeriodicRangingCodes :<value>
InitialBackoffWindowSizeforPeriodicRanging :<value>
FinalBackoffWindowSizeforPeriodicRanging :<value>