Chapter 4 - Operation and Administration Using the CLI Managing Sectors
4Motion 766 System Manual
4.9.1.2 Configuring Sector Parameters
After enabling the Sector Parameters configuration mode you can configure the
following parameters tables:
Sector Definition (refer to Section 4.9.1.2.1)
Sector Reserved (refer to Section 4.9.1.2.2)
4.9.1.2.1 Configuring Sector Definition Parameters
The Sector Definition table enables configuring the main properties of the Sector.
To configure the Sector Definition parameters, run the following command:
npu(config-sector-params-1)# sector-definition [sector-name <string (32)>]
[heading <(0 to 359 StepSize 1)>] [width <(0 to 359 StepSize 1)>]
Syntax
Description
Parameter Description Presence Default
Value
Possible Values
<(1 to 6 StepSize 1)> The Sector ID Mandatory N/A 1-6
heading <(0 to 359
StepSize 1)>
The sector heading
(The center angle of
the sector), in
degrees.
Mandatory
when creating
a new Sector
N/A 0 - 359
width <(0 to 359
StepSize 1)>
The planned sector
coverage, in degrees.
Mandatory
when creating
a new Sector
N/A 0 - 359
Command
Modes
Global configuration mode
NOTE
The following examples are for sector-1 parameters configuration mode.
IMPORTANT
An error may occur if you provide an invalid value for any of these parameters. Refer the syntax
description for more information about the appropriate values and format for configuring these
parameters.