User Manual

Chapter 4 - Operation and Administration Using the CLI Managing Sectors
4Motion 767 System Manual
4.9.1.2.2 Configuring Sector Reserved Parameters
As the name implies, the reserved parameters table enables configuring up to 4
parameters that are reserved for possible future use. In the current release none
of the reserved parameters is being used.
To configure the Sector Reserved parameters, run the following command:
npu(config-sector-params-1)# sector-reserved [reserved-1 <string
(32)>] [reserved-2 <string (32)>] [reserved-3 <string (32)>]
[reserved-4 <string (32)>].
Command
Syntax
npu(config-sector-params-1)# sector-definition [sector-name <string
(32)> ] [heading <(0 to 359 StepSize 1)> ] [width <(0 to 359
StepSize 1)> ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible Values
sector-name
<string (32)>
The sector name
(description). Must be
unique in the site (shelf).
Optional null (empty
string)
A string of up to 32
characters
heading <(0 to 359
StepSize 1)>
The sector heading (The
center angle of the
sector), in degrees.
The heading of an
associated Sector cannot
be changed.
Optional Configured
previously
0 - 359
width <(0 to 359
StepSize 1)>
The planned sector
coverage, in degrees.
Optional Configured
previously
0 - 359
Command
Modes
sector-params configuration mode
Command
Syntax
npu (config-sector-params-1)# sector-reserved [reserved-1 <string
(32)>] [reserved-2 <string (32)>] [reserved-3 <string (32)>]
[reserved-4 <string (32)>]