User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 690 System Manual
This parameter will be restored to its default value, while the other parameters
will remain unchanged.
To restore all Rate Adaptation parameters to their default value, run the following
command:
npu(config-bs-66053)# no rateadapt-general
4.8.20.3 Displaying Configuration for Rate Adaptation Parameters
To display configuration information of Rate Adaptation parameters, run the
following command:
npu# show rateadapt-general bs [<(1 to 16777215 StepSize 1)
Specify the BS ID if you want to display information for a particular BS. For
example, to display the Rate Adaptation parameters of BS 66053, run the
following command:
npu# show rateadapt-general bs 66053
Do not specify this parameter if you want to view information for all existing BSs.
To display information for all BSs, run the following command:
npu# show rateadapt-general bs
NOTE
Refer to Section 4.8.20.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# rateadapt-general [dl-basicrate ] [ul-basicrate
] [mincinr-qpsk-1by2-rep6 ] [mincinr-qpsk-1by2-rep4 ]
[mincinr-qpsk-1by2-rep2 > ] [mincinr-qpsk-1by2 ]
[mincinr-qpsk-3by4 ] [mincinr-qam16-1by2 ] [mincinr-qam16-3by4 ]
[mincinr-qam64-1by2 ] [mincinr-qam64-2by3 ] [mincinr-qam64-3by4 ]
[mincinr-qam64-5by6 ]
Privilege
Level
10
Command
Modes
bs configuration mode