User Manual

Chapter 4 - Operation and Administration Using the CLI NPU Configuration
4Motion 448 System Manual
4.3.14.3.1 Configuring Power Feeders
To configure the AU ports connected to the ports of a specific Power Feeder, run
the following command:
npu(config)# config pfUnitNo <pfunit no (1-4)> pfPortNo <pfport no
(1-4)> pfAuSlotNoDestination <AuslotNoDestination (-1,1-4,7-9)>
pfAuPortNoDestination <pfAuPortNoDestination (-1,1-4)>
Command
Syntax
npu(config)# config pfUnitNo <pfunit no (1-4)> pfPortNo <pfport no (1-4)>
pfAuSlotNoDestination <AuslotNoDestination (-1,1-4,7-9)>
pfAuPortNoDestination <pfAuPortNoDestination (-1,1-4)>
Privilege
Level
10
Syntax
Description
Parameter Description Prese
nce
Default
Value
Possible
Values
pfUnitNo
<pfunit no
(1-4)>
The Power Feeder unit
number.
Mandatory N/A 1-4
pfPortNo
<pfport no
(1-4)>
Each combination
of Power Feeder
Unit Number and
Port Number can
appear in a
maximum of one
Power Feeder
instance
The Power Feeder port
number
Mandatory N/A 1-4
pfAuSlotNoDest
ination
<AuslotNoDesti
nation
(-1,1-4,7-9)>
The AU Slot number.
-1 means none.
Mandatory -1 (none) -1 (none), 1-4,
7-9