User's Manual
Table Of Contents
- BreezeMAX CPEs Product Manual
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - Products Description
- Chapter 2 - Installation
- 2.1 Installing the ODU of the PRO-S CPE
- 2.2 Installing the IDU-1D Indoor Unit of the PRO-S CPE
- 2.3 Installing the Si CPE
- 2.4 Installing the 3.5 GHz Detached Antenna
- 2.5 Installing the 2.3/2.5 GHz Detached Antenna
- Chapter 3 - Commissioning
- Chapter 4 - Operation
- 4.1 The SU Installer Monitor Program
- 4.2 Using the Monitor Program
- 4.3 The Main Menu
- 4.4 Unit Control Menu
- 4.5 Registration Parameters Menu
- 4.6 BST/AU ID Parameters Menu
- 4.7 ˘Radio Parameters Menu
- 4.8 Performance Monitoring Menu
- 4.9 Multirate and ATPC Parameters Menu
- 4.10 ˘SU Parameters Summary
- Appendix A - The Web Configuration Server
- Appendix B - Troubleshooting
- Glossary
Radio Parameters Menu
BreezeMAX CPEs Product Manual 95
F(1) = Start Frequency + Main Step,
F(2) = Start Frequency +2*Main Step,...
End Frequency is the upper limit.
The Intermediate Steps can be used to define additional frequencies using a finer
resolution. The intermediate steps are defined as follows:
For example, If Bits 0, 1 and 4 are set to 1 and all other Bits are set to 0, the
scanned frequencies are: Start Frequency, Start Frequency + 125 KHz, Start
Frequency + 500 KHz, Start Frequency +N*Main Step, Start Frequency +N*Main
Step + 125 KHz, Start Frequency +N*Main Step + 500 KHz (N=1, 2,...). End
Frequency is the upper limit for the scanned frequencies).
Table 4-1: Intermediate Steps
Bit Effect on scanned frequencies set when set to 1
Bit 1 Include Start Frequency. The scanned frequencies set include Start Frequency, Start
Frequency + N*Main Step (N=1, 2,...). If Bit 0 is set to 0, Start Frequency is not included.
Bit 2 Add steps of 125 KHz.
Include in scanned frequencies Start Frequency + N*Main Step + 125 KHz (Start + 125 KHz is
scanned only if Bit 0 =1)
Bit 3 Add steps of 250 KHz.
Include in scanned frequencies Start Frequency + N*Main Step + 250 KHz (Start + 250 KHz is
scanned only if Bit 0 =1)
Bit 4 Add steps of 375 KHz.
Include in scanned frequencies Start Frequency + N*Main Step + 375 KHz (Start + 375 KHz is
scanned only if Bit 0 =1)
Bit 5 Add steps of 500 KHz.
Include in scanned frequencies Start Frequency + N*Main Step + 500 KHz (Start + 500 KHz is
scanned only if Bit 0 =1)
Bt 6 Add steps of 625 KHz.
Include in scanned frequencies Start Frequency + N*Main Step + 625 KHz (Start + 625 KHz is
scanned only if Bit 0 =1)
Bit 7 Add steps of 750 KHz.
Include in scanned frequencies Start Frequency + N*Main Step + 750 KHz (Start + 750 KHz is
scanned only if Bit 0 =1)
Bt 8 For bandwidth of 3.5 MHz: Add steps of 875 KHz.
Include in scanned frequencies: Start Frequency + N*Main Step + 875 KHz (Start + 875 KHz is
scanned only if Bit 0 =1)
For bandwidth of 5 MHz: Add steps of 1250 KHz.
Include in scanned frequencies: Start Frequency + N*Main Step + 1250 KHz (Start + 1250 KHz
is scanned only if Bit 0 =1)