102 Operation
Chapter 4 - Operation
4.9.3 Disable ATPC and Set Tx Power
Select this option to temporarily disable ATPC for testing purposes. You will be
prompted to enter the requested Tx Power. The minimum Tx Power is -26 dBm.
The maximum Tx Power is 20 dBm in PRO-S CPE or 22 dBm in Si CPE.
The default Tx Power is the last power level used before the ATPC algorithm was
disabled.
Upon completing the test, enable ATPC to resume normal operation. If not enabled
manually, ATPC will be enabled automatically after the next reset or following
termination of the Telnet session.