User's Manual
Table Of Contents
- BreezeMAX CPEs Product Manual
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - Products Description
- Chapter 2 - Installation
- 2.1 Installing the ODU of the PRO-S CPE
- 2.2 Installing the IDU-1D Indoor Unit of the PRO-S CPE
- 2.3 Installing the Si CPE
- 2.4 Installing the 3.5 GHz Detached Antenna
- 2.5 Installing the 2.3/2.5 GHz Detached Antenna
- Chapter 3 - Commissioning
- Chapter 4 - Operation
- 4.1 The SU Installer Monitor Program
- 4.2 Using the Monitor Program
- 4.3 The Main Menu
- 4.4 Unit Control Menu
- 4.5 Registration Parameters Menu
- 4.6 BST/AU ID Parameters Menu
- 4.7 ˘Radio Parameters Menu
- 4.8 Performance Monitoring Menu
- 4.9 Multirate and ATPC Parameters Menu
- 4.10 ˘SU Parameters Summary
- Appendix A - The Web Configuration Server
- Appendix B - Troubleshooting
- Glossary
16 System Description
Chapter 1 - Products Description
1.6.2 Data Communication (Ethernet Port)
1.6.3 Configuration and Management
Typical Sensitivity
(BER=1E-6)
Modulation
& Coding
Minimum
SNR (dB)
Sensitivity (dBm)
@ 3.5 MHz BW
Sensitivity (dBm)
@ 5 MHz BW
BPSK 1/2 2.5 -98.50 -97
BPSK 3/4 4.8 -95.5 -94
QPSK 1/2 5.9 -94.5 -93
QPSK 3/4 8.6 -91.5 -90
QAM16 1/2 11.4 -88.5 -87
QAM16 3/4 14.8 -85.5 -84
QAM64 2/3 20 -80.5 -79
QAM64 3/4 20.9 -79.5 -78
Table 1-13: Si CPE Data Communication (Ethernet Port)
Item Description
Standard Compliance IEEE 802.3 CSMA/CD
Maximum Packet Size (including 4 CRC bytes) 1550 Bytes
Speed 10/100 Mbps, Half/Full Duplex with Auto Negotiation
Table 1-14: Si CPE Configuration and Management
Item Description
Local Management via Ethernet Port
Telnet
Built-in web configuration server (using PC or PDA with http
browser)
Si CPE Installation Utility
Remote Management Via the Base Station
Software upgrade
Using TFTP via the Base Station
Using TFTP via Ethernet port
Configuration upload/download
Using TFTP via the Base Station
Using TFTP via Ethernet port
Table 1-12: Si CPE Radio Specifications