User's Manual

Table Of Contents
40 Installation
Chapter 2 - Installation
* After power-up, the SIGNAL LEDs illuminates for a few seconds until self-test is
finished.
2.3.3 RESET Button
The RESET button is located on the bottom side of the unit:
SIGNAL Link Quality Indication
LEDS 1 - 7 Off, STATUS is green: 3 dB SNR < 5 dB
LED 1 On: 5 dB SNR < 8 dB
LEDs 1 - 2 On: 8 dB SNR < 12 dB
LEDs 1 - 3 On: 12 dB SNR < 15 dB
LEDs 1 - 4 On: 15 dB SNR < 18 dB
LEDs 1 - 5 On: 18 dB SNR < 20 dB
LEDs 1 - 6 On: 20 dB SNR < 25 dB
LEDs 1 - 7 On: SNR 25 dB
LEDs 1 - 7 Blinking simultaneously ((300ms on, 300ms off):
RSSI -20 dBm (saturation)
LEDs 1 - 7 Blinking one after the other (LED-1: 200ms on then
off, LED-2: 200ms on then off, up to LED-7 and then LED-1
again): During full frequency scan.
LEDs 1 - 7 Blinking as follows: LED 4 lights, after 200ms LEDs
3 & 5 lights, after 200ms LEDs 2&6 lights, after 200ms LEDs
1&7 lights, after 200ms all the LEDs are extinguished and then
the sequence is repeated. During Best AU selection process.
SCAN button Initiating Scanning Mode
Press for less than 3 seconds to initiate Best AU selection
process without full scanning. It means that the CPE scans
only the AUs detected in the last full scan. The LEDs will be
blinking as mentioned above for Best AU operation.
Press for 3 seconds or more to initiate full scan, prepare an
updated the best AU list and select the best AU. The LEDs will
be blinking as mentioned above for full scan operation.
RF (behind cap) SMA Jack Connection to detached antenna
Table 2-7: Si CPE Top Panel Components
Name Description Functionality