BreezeMAX CPEs Product Manual 79
4.4.2 Reset Unit
Select this option to reset the unit. To avoid unintentional reset, you will be
prompted to confirm the reset request. Changes to most of the configurable
parameters are applied only after reset. Refer to Section 4.10 for information on
which parameters are changeable in run time and which changes are applied only
after reset.
4.4.3 Change Password
Select this option to change the password. You will be prompted to enter the new
password. After pressing enter, you will be prompted to re-enter the new
password.
Valid passwords: Up to 20 printable characters.
Default password: installer
4.4.4 SW Versions Control
The SU can contain two SW versions:
Main: Each time the SU resets it will reboot using the version defined as Main.
Shadow: Normally the Shadow version is the backup version. Each time a new
SW File is downloaded to the SU, it will be stored as a Shadow version,
replacing the previous Shadow Version.
The typical process of upgrading to a new SW version includes the following steps:
1 Download the new SW File to the SU. It will be stored as the Shadow version.
2 Reset and run the unit from its Shadow version. Note that at this stage, after
reset the unit will reboot from its previous Main version.
3 If you want to continue using the new version, swap the Shadow and Main
versions. The new version is now defined as Main, and will be used each time
the unit reboots. The previous version is defined now as Shadow.
The SU functions as a TFTP client, enabling the loading of SW files from a TFTP
server.
NOTE
Notify the administrator of the new password!