BreezeMAX CPEs Product Manual 27
2.1.5 Connectors
2.1.6 Connecting the Cables
2.1.6.1 Connecting the Grounding Cable
The Grounding screw (marked ) is located on the back panel of the ODU (see
Figure 2-1).
1 Connect one end of a grounding cable to the grounding screw and tighten the
grounding screw firmly.
2 Connect the other end of the grounding cable to a good ground (earth)
connection.
2.1.6.2 Connecting the Antenna Cable
Figure 2-5: Bottom Panel of the ODU (SE model, without sealing covers)
Table 2-2: CPE-ODU-PRO Connectors
Name Connector Functionality
IDU COM 10/100Base-T (RJ-45) Connection to the IDU
SAU Special mini USB Connection to SAU
(ANT, only in SE model) N-Type jack, 50 Ohm Connection to an external antenna
To connect the grounding cable:
To connect the RF cable (units with external antenna):