User's Manual

Table Of Contents
Using the Monitor Program
BreezeMAX CPEs Product Manual 73
4.2 Using the Monitor Program
4.2.1 Accessing the Monitor Program
1 The Monitor program uses the fixed IP address 192.168.254.251 with the
subnet mask 255.255.255.0. The PC used for accessing the Monitor program
should be configured accordingly. It is recommended to set the PC's IP address
to 192.168.254.250, which is the default TFTP Server IP address (required for
downloading SW versions and for downloading/uploading configuration files).
2 Co
nnect the PC to the Ethernet port, using a straight cable.
3 Run the Telnet program connecting to 192.168.254.251. The Enter the
password prompt is displayed. Enter the password and press the Enter key.
4 The Main menu of the SU Installer Monitor program is displayed, enabling
access to the required parameters configuration and performance monitoring
options.
4.2.2 Using the Program
This section describes the Monitor program structure and navigation rules.
To access the Monitor program:
NOTE
The IP address 192.168.254.251 is used only for the Monitor program. This is not the IP address used
by the unit for other purposes. The IP parameters for management purposes are allocated by the NPU
during the Network Entry process.
NOTE
Following three consecutive failures to enter the correct password, access to the Monitor program will
be blocked for 5 minutes.The factory default password is "installer".If you forgot the password, type
"help" to get a challenge string consisting of 24 characters. Contact Customer Service and give them
the challenge string (after user identification) to receive a one-time password. You can use this
password only for a single entrance to the program. The password must be changed during the
session to a different "permanent" password. The administrator should be notified of this new
password. Five consecutive errors in entering the one-time password will invalidate it, and a new
challenge string should be used to receive a new one-time password.