User's Manual

Table Of Contents
98 Operation
Chapter 4 - Operation
4.7 Radio Parameters Menu
The Radio Parameters menu includes the following options:
Show
Frequency Scanning Parameters
Antenna Parameters (applicable only for Si CPE)
Rx Attenuator (applicable only in the 2.3 GHz band)
Bandwidth (not applicable if the SU supports only a single bandwidth)
4.7.1 Show
Select this option to view the Bandwidth, Antenna Selection and Rx Attenuator
parameters (if applicable). These parameters are applied only after reset.
Therefore, actual values may differ from configured values. For each parameter
both the current and configured values are displayed.
4.7.2 Frequency Scanning Parameters
The Frequency Scanning menu enables viewing and updating the set of
frequencies to be used during the scanning process. The list of frequencies that
participate in the scanning process includes a set of frequencies belonging to the
scanning range and/or a set of up to 10 discrete frequencies.
The scanning range is defined by Start Rx Frequency, End Rx Frequency,
Scanning Main Step and Intermediate Steps. The set of frequencies to be scanned
is defined as follows:
The “Main Frequencies” are defined by the Start Frequency and Main Step, using
the formula F(N) =Start Frequency + N*Main Step;
F(1) = Start Frequency + Main Step, F(2) = Start Frequency +2*Main Step,...
End Frequency is the upper limit.
The Intermediate Steps can be used to define additional frequencies using a finer
resolution. The intermediate steps are defined as follows: