64 Commissioning
Chapter 3 - Commissioning
3.2.2 Configuration Tools
Two options for local configuration and monitoring are incorporated into all SUs:
The Installer Monitor program, based on a user-friendly CLI (Command Line
Interface). The Installer Monitor program can be accessed using Telnet.
The web Configuration Server, providing a web-based GUI. The Web
Configuration Server can be accessed using a PC/Notebook or a Pocket
PC/PDA with a web browser.
The SU may be delivered with the operator’s default settings already configured in
the FLASH memory. If there is need to change these settings then the only
parameters that should be configured are the end user’s credentials (User Name
and User Password). In certain scenarios (where the MAC address of the unit is
known to the system administrator and services are provisioned based on this
MAC address), there is no need to configure the credentials. the SU will
automatically use the credentials User Name = MAC address, User Password =
quickynikynyoky.
If a Smart Card is used in an Si CPE, the unit will always use the configuration
incorporated into the Smart Card. Once the Smart Card is removed, the SU will
load the configuration from the FLASH.
If a WiMAX Modem Application utility is used, the SU will load to the FLASH and
use the operator’s configuration from the WiMAX Modem Application CD. This
configuration may be changed via the utility’s configuration screens. For more
details refer to the WiMAX Modem Application documentation.
3.2.3 Using the Configuration Tools
1 To configure parameters using Telnet, connect a PC/Notebook to the Ethernet
port of the IDU, using a straight Ethernet cable.
NOTE
Some parameters are changed to their new values only after reset (refer to Section 4.11 for more
details). Once the basic parameters are configured, the unit should be reset in order to activate the
new configuration.
To configure the SU's basic parameters: