Aligning the PRO-S CPE’s Antenna
BreezeMAX CPEs Product Manual 69
* After power-up of the ODU, the all LEDs illuminate until self-test has completed.
Table 3-2: SAU LEDs
Name Description Functionality
AL Alarm indication
Off - ODU is OK, diagnostic test passed
Red - ODU failure
PW Power indication
Off - ODU is not powered or 3.3 VDC failure
Green - ODU power to SAU is OK
ET Ethernet link status
indication
(Ethernet integrity)
Off - No Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit’s
Ethernet port
Green- Ethernet connectivity has been
detected between the outdoor unit and the
device connected to the indoor unit’s
Ethernet port
WLNK Wireless link status
indication
Off - The SU is not connected with a Base
Station
Orange on - The SU is connected with and
receives services from the Base Station
(Network Entry completed). Link Quality is
indicated by LEDs 1-9 as described in
Table 3-3. below.
Blinking orange - Authentication failed. The
reason is provided by Link Quality Bar
LEDs:
If LEDs 6, 7 and 8 are on: Authentication
reject by RADIUS server.
If LEDS 7 and 8 are on: Rejected by Base
Station (Duplicate SU Name in database).
If LED 8 is on: Authentication Timeout,
re-authentication failure (connection to
RADIUS server lost or Shared Secret
mismatch)