User's Manual

Table Of Contents
Chapter 4 - Link Configuration Link Diagnostic Tools
Alvarion BreezeNET B130/B300 GigE 63 Technical User Manual
4.1.5.1 How to Use
Turning on:
1 For turning RapidView on simply push the "Power button".
2 Device LEDs will light up for 2 seconds.
3 Device will perform constant tries to connect to ODU. If device's power is
normal Power/ODU connection LED (1) will blink 1 time per second. If device's
power is low LED 1 will blink 4 times per second in turn with not lighting
intervals.
4 Once ODU link is established, LED 1 stops blinking (if power is normal) and
device's interfaces status are shown by LEDs 2-6.
5 1 time per second device updates its status output.
6 If ODU link will be broken, LEDs 2-6 will go out after 2 seconds and LED 1 will
start blinking 1 time per second.
Diagnostic device connection to ODU should be done via console port of the ODU.
Once link is up between ODU and diagnostic device the following record is put in
ODU system log:
Exact radio interface names depend on wireless equipment configuration.
When diagnostic device is unplugged from the following record is put in ODU
system log:
LEDs modes description:
ODU status monitoring via diagnostic device is performed by its LEDs indication.
LEDs modes and ODU status correspondence is shown in the following table:
Connected test unit. Begin service communication over console.
Test unit detected: rf0 - rf5.0
Test unit disconnected. Return to normal console mode.