User's Manual

Table Of Contents
In-building Cellular Solution for Commercial Buildings UDC Software Configuration Tool
BreezeCELL
20
After logging in, the main screen will be the Alarms Log.
12.2 Configuring a Global Parameter Set (GPS)
A group of remote units with the same frequency requirements should be allocated a common
parameter set called GPS. Each GPS include:
Cellular (Air) Up Link Frequency
Cellular (Air) Down Link Frequency
CATV Up Link Frequency
CATV Down Link Frequency
A change in the GPS will generate a change in each remote unit using this GPS.
Note: You can’t edit the GPS name, as this is used by its associated remote units
12.2.1 Adding a GPS
1. From the menu GPS MAINTENANCE choose Add Group Parameters
2. Press the ADD GPS button on the top left side of the screen. The GPS configuration table will
appear.
3. Enter a Name and Description of the GPS. The name should be unique.
4. Choose the technology from the list: GSM 900, GSM 1800, UMTS, PCS, iDEN, US Cellular
5. Choose the channel Bandwidth of the remote unit (factory hardware preset)
6. Fill in the Cellular and CATV frequencies according to your frequency plan so that there is a match
with the channel bandwidth and the technology. The frequency units are [KHz]
7. Press Save to update the database
8. Repeat steps b to g for each GPS required in the network