User's Manual

Table Of Contents
In-building Cellular Solution for Commercial Buildings UDC Software Configuration Tool
BreezeCELL
22
Number of instances - single [1] or dual technology [2]
GPS1 & GPS2 choose from defined GPS list
4. Press the Save button to input the remote unit into the database
12.4 Installing a Remote Unit
Once a remote unit is installed in the field, it will communicate with the monitoring system and will
receive operational configuration parameters. There are two possible scenarios:
Uninstalled remote unita remote unit which is defined in the database
Undefined remote unita remote unit which was not previously defined in the database
12.4.1 Uninstalled Remote Unit
Adding a new remote unit into the database will generate an uninstalled remote unit entry. This refers
to a remote unit that was properly defined in the system and should be installed in the field. At the
moment the remote unit is physically installed, it communicates with the monitoring system, all
parameters are verified and downloaded to the remote unit, after that the remote unit receives a
permission to radiate.
12.4.2 Undefined Remote Unit
A remote unit that was physically installed in the field, but was not entered into the database prior to
installation. Such a remote unit will be transferred to the undefined remote unit s list and requires
operator configuration of the relevant parameters in the monitoring system to become operational.
12.4.3 Adding an Undefined Remote Unit into the Database
1. From the remote units Lists menu choose Undefined remote units
2. Choose the relevant remote unit from the list and press the EDIT button on the left side of the
remote unit entry. A configuration screen will appear.
3. Enter the remote unit information
Location [Free text]
Information [Free text]
Number of instances - single [1] or dual technology [2]