User's Manual
Table Of Contents
- 1 Introduction
- 2 The Concept
- 3 BreezeCELL Architecture
- 4 BreezeCELL Network Elements
- 5 Frequency Allocations
- 6 MIMO Support
- 7 Monitoring & Control
- 8 Installation Requirements and Procedures
- 9 Headend Equipment Installation
- 9.1 Connector Information
- 9.2 Rack Installation
- 9.3 Connecting the BreezeCELL Equipment
- 9.4 Connecting the Monitoring System
- 9.5 Connecting External Alarms
- 9.6 Connecting the Base Stations
- 9.7 UDC Configuration
- 9.8 Pilot Master/Slave Configuration
- 9.9 Measurements
- 9.10 Connecting to the Coax TV Networks
- 9.11 Measurements
- 9.12 Localized Testing Port
- 9.13 Determining BTS Output Power VS. Remote Unit Output Power
- 10 Coax Network Amplifier Installation (if applicable)
- 11 Remote Unit Installation
- 12 Preparing for Remote Unit Installation
- 13 Normal Operations
- 14 Acceptance Testing
In-building Cellular Solution for Commercial Buildings UDC Software Configuration Tool
BreezeCELL
40
10. Press Program Device
11. The red VPP and VDD LEDs on the programmer will be turned on and a status window will be
displayed.
A.4. Tools
On the main menu press Tools
A.4.1. Recall Configuration from a Device
The configuration of a UDC can be recalled from a pre-configured device.
1. Connect the device to the programmer
2. Press the Read Device button
3. The red VPP and VDD LEDs on the programmer will be turned on and a status window will be
displayed.
4. The device parameters will be displayed in the Read Device window.
A.4.2. Use Device Configuration
The recalled parameters can be used to configure a new device
1. Press the Use Frequencies button.
2. The device parameters will be transferred to the main configuration template.
3. Verify all inputs
4. Press Program Device.
Figure 18: Tools Screen
A.5. Configuration Management
Configurations can be saved and restored from a database. Up to 1,000 different configurations can be
loaded and displayed using the File menu.