Accessory Installation
BreezeNET PRO.11 Series 6-4 User’s Guide
3. Connect the LNA 10 RF input directly to the receive antenna, as
close as possible.
4. Attach the LNA 10 RF output directly to the RF cable going down
to the receive antenna connector on the BreezeNET PRO.11 unit.
5. Connect the RG-59 coaxial cable which leads down to the Power
Inserter to the “Signal and Power out” connector on the LNA 10.
6. Connect the Power Inserter to the power supply (both are indoor
units).
7. For transmission, use a separate antenna connected to the other
antenna connector (transmit antenna) of the BreezeNET unit.
Figure 6.2: LNA 10 Connections Diagram