User's Manual

Basic Installation
BreezeNET PRO.11 Series 2-5 User’s Guide
2.6. Check Unit Functionality using LED indicators
Check the unit functionality by using the LEDs on the front panel. The
following tables describe the front panel LEDs for Stations (SA-10, SA-40)
and Bridges (WB-10), and for Access Points.
2.6.1. Station (SA-10, SA-40) and Bridge (WB-10) LEDs
Name Description Functionality
PWR power supply On – After successful power up
Off – Power off
WLNK WLAN Link On – Unit is synchronized or associated with an AP
Off – Unit is not synchronized or associated with an AP
ETHR Ethernet activity On – Reception on Ethernet port
Off – No reception on Ethernet port
QLT Quality of reception
very low quality reception or
not synchronized with Access Point
less than -81 dBm
low quality reception
(usually enabling 1 Mbps traffic)
from -81 to -77 dBm
medium quality reception
(usually enabling 2 Mbps traffic)
from -77 to -65 dBm
high quality reception
(usually enabling 3 Mbps traffic)
greater than -65 dBm