User's Manual

Accessory Installation
BreezeNET PRO.11 Series 5-1 User’s Guide
5. ACCESSORY INSTALLATION
This chapter introduces some of the accessories available for specific
installations, and describes how to install them.
5.4. AL 1 Lightning Arrestor
The AL 1 Lightning Arrestor is used to protect transmitters and receivers
from transients originating from lightning or EMP.
The AL 1 is gas tube-based and is not radioactive. The gas discharge tube
can sustain several transients if the time period between transients is
sufficient to allow the tube to cool down.
For technical specifications, refer to section 8.2.2, Specifications for AL 1
Lightning Arrestor.
Figure 6.4: AL-1 Connection Block Diagram
One of the female-type N connectors is mounted directly through a hole in
the shelter wall and held in place with a lockwasher and nut.