BreezeACCESS MMDS Base Station Equipment Installation Manual July, 2000 Cat. No.
Front Matter © 2000 by BreezeCOM Ltd. All rights reserved. No part of this publication may be reproduced in any material form without the written permission of the copyright owner. Trade Names BreezeACCESS, BreezeNET, BreezeLINK, BreezeVIEW, BreezeMANAGE and WIX are trade names of BreezeCOM Ltd. Other brand and product names are registered trademarks or trademarks of their respective companies. Statement of Conditions The information contained in this manual is subject to change without notice.
Front Matter limited to, loss of profits or revenues, loss of use or damage to any associated equipment, cost of capital, cost of substitute products, facilities or services, downtime costs or claims resulting from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, service, repair, maintenance or use of the products. In no event shall the company’s liability exceed the purchase price denoted on the invoice.
Table of Contents 1. INTRODUCTION ..................................................................................................................... 1 2. BASIC INSTALLATION ......................................................................................................... 2 2.1 Packing List – Modular Shelf Equipment ............................................................................. 2 2.1.1 BS-SH Base Station Shelf...........................................................................
Table of Contents 4.2 Verifying Correct Operation of the AU-A/E-NI ................................................................. 23 4.3 Verifying Correct Operation of the Outdoor Unit............................................................... 24 5. SPECIFICATIONS ................................................................................................................. 27 5.1 Radio ................................................................................................................
Table of Contents Table of Figures Figure 2-1. Holes/Grooves/Screw Holes................................................................................... 7 Figure 2-2. AU-RA 2" Pole Mounting Installation Using the Supplied Brackets .................... 7 Figure 2-3. AU-RE 3" Pole Mounting Installation Using the Supplied Brackets ..................... 8 Figure 2-4. Shelf Slot Assignments......................................................................................... 10 Figure 2-5.
Introduction 1. INTRODUCTION This manual describes installation guidelines for BreezeACCESS MMDS base station equipment, including the stand-alone AU-E/A-NI-MMDS Access Units and the modular AU-E/A-BS-MMDS Units with the BS-SH rack mounted shelf. The BreezeACCESS IP Broadband Wireless Local Loop (WLL) system allows access service providers to provide high-speed IP connectivity services to their subscribers.
Basic Installation 2. BASIC INSTALLATION 2.1 Packing List – Modular Shelf Equipment 2.1.1 BS-SH Base Station Shelf • BS-SH shelf (with blank panels) • Rubber legs for optional desktop installation Note: Unless ordered otherwise, each BS-SH will be shipped with one BS-PS power supply installed. 2.1.
Basic Installation 2.2 Packing List – Stand-alone AU-A/E-NI Access Unit • AU-NI indoor unit • Outdoor unit: ⇒ AU-RA with integral antenna or ⇒ AU-RE with a connector to an external antenna (not included) • AU-PS power supply with a mains power cord • Pole mounting kit for the Outdoor unit (with two brackets, four sets of screws, nuts and washers) • Wall mounting kit for the AU-NI unit 2.
Basic Installation • The AU-RE outdoor unit should be installed as near as possible to its antenna. Note: • The distance between any two antennas should be greater than 40 cm. The outdoor unit is connected to the indoor unit by means of a coaxial IF cable carrying signals, controls and power. The IF frequency is 440 MHz. The maximum allowed attenuation of the IF cable is 15dB and its maximum allowed DC resistance (the sum of the DC resistance of the inner and outer conductors) is 1.5 ohm.
Basic Installation The system complies with the ETS 300 385 standard and is protected against secondary lightning strikes when its outdoor unit is properly grounded according to the applicable country-specific industry standards for protection of structures against lightning. Failure to do so may void the BreezeACCESS product warranty and may expose the end user or the service provider to legal and financial liabilities.
Basic Installation 2.5 Installing the Outdoor Radio Unit 2.5.1 Mounting the Outdoor Unit The outdoor unit can be secured to the pole using one of the following options: • Special brackets (supplied with each unit). There are two pairs of screw holes, allowing use of the special brackets with various pole widths. • U-bolts - size A (inner installation holes, up to 2" pole). • U-bolt - size B (outside installation holes, up to 3" pole). • Metal bands (9/16” wide, minimum 12” long).
Basic Installation G roo ve s fo r Insertion o f 9 /16 ” M e tal B a nd U -B olts (3” P ole ) U -B olts (2” P ole ) B ra cke t S cre w s Figure 2-1. Holes/Grooves/Screw Holes Figure 2-2.
Basic Installation Figure 2-3.
Basic Installation 2.5.2 Connecting the Antenna Cable (AU-RE) Connect an RF cable between the ANT connector (located on the bottom panel of the unit, shown in Figure 4-1) and the antenna. 2.5.3 Connecting the Ground and IF Cables The Ground terminal (marked ) and the IF cable connector (marked IF) are located on the bottom panel of the Outdoor unit, shown in Figure 4-1. 1. Connect one end of the grounding cable to the Ground terminal and connect the other end to a good ground connection. 2.
Basic Installation 2.6 Installing the Modular Shelf Indoor Equipment 2.6.1 BS-SH Slot Assignments The Base Station shelf has ten slots, as shown in Figure 2-4.
Basic Installation 2.6.2 The BS-AU The BS-AU front panel is shown in Figure 2-5. B S -A U PW R ALR M W LN K MASTER RESET OFF ON ETH IF MON Figure 2-5. BS-AU Front panel The BS-AU provides the following interfaces: An Ethernet connector (ETH) for connecting the BS-AU to the network. This connector should be connected to a straight Ethernet cable. An IF connector for connecting the BS-AU to an outdoor AU-RE or AU-RA radio unit.
Basic Installation The BS-AU front panel LEDs are described in Table 2-2.
Basic Installation 2.6.3 The BS-PS The BS-PS provides -48VDC to all the modules installed in the BS-SH rack. The BS-PS front panel is shown in Figure 2-6. B S -P S PW R 5V 12 V ON ON OFF -48 V Figure 2-6. BS-PS Front Panel The BS-AU provides a single connector for connecting the -48VDC power source to the module. The color codes of the cable wires are: black red -48VDC + (Return) The switch turns the mains power to the power supply ON and OFF.
Basic Installation 2.6.4 Shelf and Modules Installation Procedure 1. Install the BS-SH rack in a 19” cabinet (or place on an appropriate shelf/table). When mounted the BS-SH on a desktop, screw on the rubber legs shipped with unit. 2. Carefully insert the BS-PS Power Supply and the BS-AU modules into their intended slots and push firmly until they are securely locked; refer to Section 2.6.1 for a description of the slot assignments. Close the captive screws attached to each module.
Basic Installation 2.7 Installing the AU-NI Indoor Unit 1. Place the AU-NI unit in an appropriate location on a shelf or a table. The unit can be wall mounted using the installation materials provided with the unit. Use a 6mm (1/4”) drill and the supplied template plate for easy and accurate marking of the holes. 2. Connect the AU -PS power cord to the DC In jack (marked DC-12V) located on the rear panel of the Indoor unit (shown in Figure 2-6). 3.
Basic Installation 6. Use a straight Ethernet 10baseT cable to connect the base station network (e.g., a hub, switch or router) to the Ethernet port (marked ETH) located on the rear panel of the AU-NI unit.
Configuring System Parameters 3. CONFIGURING SYSTEM PARAMETERS After completing the installation process as described in the preceding section, proceed with configuration of the basic system parameters. This section covers the configuration of basic installation parameters. Refer to the Administration Manual for information related to other parameters. Note: Optionally, the product can be configured using Telnet over the Ethernet port, after setting the IP address.
Configuring System Parameters Unit Type BreezeACCESS (AU) Official Release Version – 2.1.1 Release Date: Software Version No. Tue Mar 07 11:21:22 2000 Main Menu ===================== 1 – Info Screens 2 – Unit Control 3 – Basic Configuration 4 – Site Survey 5 – Advanced Configuration BreezeACCESS >>> Unit Name Figure 3-1. Main Menu The appearance of the displayed Main Menu varies in accordance with the access level. • For users with read only access rights, only the Info Screens option is displayed.
Configuring System Parameters 4. Operate the monitor program as follows: • Type an option number to open/activate the option. You may need to press the Enter key in some cases. • Press the Esc key to exit a menu or an option. • You can log-out and exit the monitor program at any time by simultaneously pressing the Ctrl and X keys. • Reset the unit after making configuration changes for the new values to take effect.
Configuring System Parameters 1. From the main menu, type 3 to access the Basic Configuration menu. BreezeACCESS (AU) Official Release Version – 2.1.
Configuring System Parameters 3.3 Reset Unit 1. From the main menu, type 2 to access the Unit Control menu. 2. Type 1 to access the Reset Unit menu. Type 1 to reset the unit so that new configuration settings are applied. Note: Should you make any mistakes during configuration or encounter any problems associated with system configuration parameters, you may configure the unit back to the factory defaults, as follows: Type 2 in the Unit Control menu to access the Set Factory Defaults menu.
Configuring System Parameters BS Equipment Installation Manual 22 BreezeACCESS MMDS Series
Verifying correct operation 4. VERIFYING CORRECT OPERATION 4.1 Verifying Correct Operation of the AU-A/E-BS After completing the installation as described above, the system starts operation. To verify correct operation, view the LED indicators located on the front panel of the BS-AU modules as shown in Table 2-2on page 12. Note: If the Access Units are not synchronized, reset the Master BS-AU unit and then the Slave units to re-synchronize them. 4.
Verifying correct operation Name Description Yellow LED Functionality On - Power On Off – Power is not received from the Indoor unit 8 Green LEDs RSSI in 4 dB resolution starting at –91dBm Red LED Received signal strength is –40dBm or higher 4.3 Verifying Correct Operation of the Outdoor Unit To verify proper operation, view the LED indicators located on the bottom panel of the Outdoor unit as shown in Figure 4-1. ETH 1 2 V IN ALAR M ANT IF Figure 4-1.
Verifying correct operation Table 4-2 lists the various LED states.
Verifying correct operation BS Equipment Installation Manual 26 BreezeACCESS MMDS Series
Specifications 5. SPECIFICATIONS 5.1 Radio Frequency 2.500GHz –2.686GHz Radio Access Method FH-CDMA or TDMA Operation Mode Time Duplex Division Sub-Channel Bandwidth 1 MHz Frequency Setting Resolution 1 MHz Antenna Gain (AU-RA) 17 dBi, 200 Output Power (at antenna port) 27 dBm typical. Power Control range – 20 dB Sensitivity -6 (dBm at antenna port, BER 1E10 ) 1Mbps 2Mbps 3Mbps -87 -80 -71 Data Rate 3Mbps max Modulation Multilevel GFSK 5.
Specifications 5.3 Configuration and Management Local Management Via MON port, Monitor program using terminal emulation Remote Management SNMP, Telnet, TFTP Remote Management Access From Wired LAN, Wireless Link SNMP Agents MIB II, Bridge MIB, Private MIBs Security Authentication and filtering Software upgrade TFTP download 5.
Specifications 5.5 Electrical Outdoor Unit 12 VDC via the IF cable Indoor Modular Shelf Equipment -48 VDC, 200 W for a fully equipped shelf. AU (Indoor + Outdoor): 25W Indoor Su-NI Unit SU-NI: 12VDC/2.5A from SU-PS SU-PS: 100 - 240 VAC, 47-63 Hz 5.6 Mechanical Outdoor Unit AU-RE: 30cm x 12cm x 5cm, 2.2 kg. AU-RA: 30cm x 30cm x 7.2cm, 3 kg. Indoor Modular Shelf Equipment BS-SH: 19”,3U, depth 26cm, 6 kg. Fully loaded Indoor SU-NI Unit SU-NI: 13cm x 8.6cm x 3cm, 0.5 kg. SU-PS: 10cm x 6.5cm x 3.
Appendix A BS Equipment Installation Manual 30 BreezeACCESS MMDS Series
Specifications APPENDIX A. USING TELNET Use the following procedure to connect to BreezeACCESS 3.5 units via a Telnet session. 1. Connect the PC to the Ethernet port of the unit (or the hub to which the unit is connected) using a straight Ethernet cable. If you connect the PC directly to a unit that is normally connected to a hub, use a crossed Ethernet cable. You may also connect the PC to any Ethernet port on the network and communicate with the unit to be managed via the wired or wireless media. 2.