User`s guide
BreezeNET DS.11 Series User’s Guide 
2-16 
Name Description  Functionality 
ETH 
Ethernet activity/ 
connectivity indication 
OFF –Ethernet connectivity is OK. 
No traffic activity detected on the port. 
Blinking Green –Ethernet connectivity is OK, with traffic on 
the port. 
Red – No Ethernet connectivity. When this state occurs, check 
the Ethernet cable and indoor-to-outdoor cable connections. 
RSSI/Load 
BAR
  RB-DS.11: Received Signal Strength Indication 
BU-DS.11: Number of associated RB-DS.11 units 
Table 2-3: Outdoor Unit LEDs 
What to do if the Self Test Fails 
Upon failure of the self-test, the WLAN, DC Power and ETH LEDs, as well as the 
leftmost 2 LEDs of the RSSI bar are blinking synchronously. The statuses of the 
other 8 LEDs of the bar indicate the specific problem type. 
If the Self-Test fails, try the following: 
♦  Reset unit (Disconnect/reconnect the power). 
♦  Check the indoor-to-outdoor cable. 
♦  Reset to factory defaults (see page 3-29). 
If all fails, contact technical support and provide details regarding the status of the 
RSSI LEDs.