Specifications

Chapter 4 - Operation Menus and Parameters
BreezeNET B 114 System Manual
Number of Scanning Attempts parameter defines the number of times that the
process will be repeated for all relevant frequencies. A higher number may result
in a better decision at the cost of an increased scanning time during which the RB
is not operational.
Valid values: 1 - 255.
Default value: 4.
4.2.6.2.6.3 Preferred BU MAC Address
The Preferred BU MAC Address parameter defines a specific BU with which the
RB should associate. Gaining control of the RB association is a powerful tool in
network management. The Preferred BU MAC Address parameter is intended for
applications where there is a need to dictate the preferred BU with which the RB
should associate. To prevent the RB from associating with the first viable BU it
finds, the Best BU Support mechanism should be enabled. Once the RB has
identified the preferred BU based on its MAC address, it will associate with it and
terminate the scanning process. If the preferred BU is not found, the RB will
associate with a BU according to the decision reached using the best BU
algorithm.
Valid values: A MAC address string.
The default value for the Preferred BU MAC Address is 00-00-00-00-00-00 (12
zeros), meaning that there is no preferred BU.
4.2.6.2.6.4 Show Best BU Parameters and Data
The Show Best BU Parameters and Data option displays the applicable
information:
The Neighboring BU Data table displays the following details for each BU with
which the unit can communicate:
MAC Address
SNR of the received signal
RSSI of the received signal
Mark - The computed quality mark for the BU.
Full - The association load status of the BU. It is defined as full if it is already
associated with an RB. A BU whose associations load status is full cannot be
selected as the Best BU, even if its computed mark is the highest.