Chapter 4 - Operation Menus and Parameters
BreezeNET B 135 System Manual
option is disabled, there is no upper limit to the Noise Floor value on the BU
(except the one imposed by the available range), possibly leading to loss of
association for the an RB with lower SNR:
0 - Disable KeepLink
1 - Enable KeepLink
The default is 1 (Enabled).
4.2.6.2.18.2.5Channel Scan Period
The period of time, in seconds, the unit will stay on each channel to gather
information. The unit may stop recording prematurely if a 100 000 events limit is
reached.
The available range is from 2 to 30 seconds.
The default is 5 seconds.
4.2.6.2.18.2.6Automatic Scan Period
The period of time, in minutes, after which the unit will rerun the Interference
Mitigation channel scan. Setting this value to 0 will disable periodicity, allowing
only one-time manually triggered Interference Mitigation scans.
The available range is 0 (disabled) or 10 - 10080 (minutes)
Default value is 0 (disabled).
4.2.6.2.18.2.7Frequency Subset (BU only)
This setting allows you to select the channels that will be scanned during the
Interference Mitigation process. All the defined frequencies and their indexes will
be displayed. Frequencies are indexed with consecutive numbers starting from 1.
Enter the desired channels’ corresponding indexes separated by commas (for
example: 1, 4, 5, 6, 14, 18, 19) or enter A to select all defined frequencies.
4.2.6.2.18.3 Activation
Starts the Interference Mitigation process. Keep in mind that during the scan, the
BU will lose connectivity to the associated RB. A final validation is required prior
to the scan:
0 - Cancel Operation
1 - Activate Interference Mitigation (Causes Automatic Reset)
After reset, the Interference Mitigation statistics file will be updated, and
depending on the Scanning Type you defined, the unit may be configured to a new