Specifications

Chapter 4 - Operation Menus and Parameters
BreezeNET B 62 System Manual
4.2.3.2.1.2 Set Partial Factory Defaults
Select this option to reset the unit to the standard Factory Default configuration,
excluding the parameters that are required to maintain connectivity and
management access. The parameters that do not change after Set Partial Factory
Defaults are listed in Table 4-3.
Table 4-2: Parameters not changed after Set Complete Factory/Operator Defaults
Parameters Group Parameter
Unit Control Parameters All Passwords
FTP Server IP address* (see note below)
FTP Gateway IP address* (see note below)
FTP User Name* (see note below)
FTP Password* (see note below)
Ethernet Port Negotiation Mode
Unit Type
Air Interface Parameters Selected Sub Band (BU)
Frequency (BU)
DFS Required by Regulations
Frequency Subset (BU)
Antenna Gain (BU)
Country Code Parameters Selected Country Code
NOTE
The FTP parameters are not set to their default values after Set Complete Operator Defaults.
However, they are set to their default value after Set Complete Factory Defaults. Note that in this
case they are set to the default values immediately upon selecting the Set Complete Factory
Default option (even before the next reset).