F2 - sets the ending frequency for scanning in MHz. Maximal available
frequency for the given equipment model is used by default. The actual shown
ending frequency is limited by the size of the program window.
BW - sets bandwidth in MHz. Allowed values are 1/5/10/20 MHz depending
on the concrete equipment mode.
STEP - sets frequency changing step in MHz. Allowed values are 1/5/10/20
MHz but no more than defined bandwidth value.
record=SEC - starts Spectrum Analyzer in the background mode with the
specified duration time in seconds. The result is stored in the memory till the
unit's reset.
replay - allows viewing the result of the last Spectrum Analyzer scan.
To terminate the analyzer operation in any of the above modes press <ESC> or
<Ctrl/C>.