Specifications

Chapter 3 - Point-to-Point Configuration Unit’s Configuration
Alvarion BreezeNET B130/B300 GigE 26 Quick Start Guide
3.1 Unit’s Configuration
1 Choose two units.
2 Provide connectivity from PC1 to Unit1 and PC2 to Unit2 following the
procedure described in "“Getting Access to the Unit” on page 7". As a result
you should make sure that you can ping/telnet Unit1 from PC1 and
ping/telnet Unit 2 from PC2.
3 Now we will proceed to units’ configuration. From PC1 enter Unit 1 using
Telnet (Start->Run: "telnet 9.1.8.1") and from PC2 enter Unit 2 unit ("telnet
9.1.8.2").
4 Next step is configuring radio parameters of the radios. As the purpose of this
document is to show the basic settings we only will cover essential parameters
of the radio so that the connection could be established. In fact, radio has
many more other settings not mentioned below:
» Units should be configured for the same frequency. Example:
rf rf5.0 freq 5725
» Set up output power. For lab testing purposes the power can be configured
at the minimal value. Example:
rf rf5.0 txpwr 0
» Units should have same SID. SID can be chosen as any 8-digit HEX
number. Example:
rf rf5.0 sid 11223344
» Set up desired working bitrate. Example:
rf rf5.0 bitr 52000
Please note that the list of allowed bitrates can be viewed using "rf rf5.0
cap" command and may depend on the unit's modification and selected
channel width (these settings are not within the scope of this document).
5 After radio configurations are done, we need to run MINT protocol which is a
core of the unit's architecture. On both units the following command should
be executed:
mint rf5.0 start