User manual

12 Functions and operations in the tension control mode
103
STEP 2 Operate the motor
4.
Confirm that the motor
rotates without problem.
3.
Input the CW (CCW) signal.
To change the speed limit: VR2
1.
Change the control mode
to "Tension Control Mode."
To change the tension
command value: VR1
Higher
tension
value
Lower
tension
value
Higher
speed limit
Lower
speed limit
SW1
2.
Set the minimum speed.
SW2
Note
The new settings of the control mode setting switches will become effective after the
power is cycled. If a 24 VDC power supply is used, also cycle the 24 VDC power supply.
STEP 3 Were you able to operate the motor properly?
How did it go? Were you able to operate the motor properly?
If the motor does not function, check the following points:
Are the thermal terminals for regeneration resistor (TH1 and TH2) on the CN1 (shorted)?
Is any alarm present?
Are the power supply and motor connected securely?
Is the TEN LED (green) lit?
Isn’t the VR2 set to 0 r/min?
For more detailed settings and functions, refer to the following pages.
P.106