User manual

12 Functions and operations in the tension control mode
104
12.2 List of setting items
The items that can be set in the tension control mode are listed below.
You can use the data setter OPX-2A or the
data setting software MEXE02 to set
operation data or change the internal
parameters of the driver.
Parameter codes displayed on the OPX-2A
screen are shown in brackets. These codes are
also referenced in the main text herein. Use
these codes as keywords.
OPX-2A
MEXE02
For the method to set parameters with the OPX-2A or MEXE02, refer to the operating manual for each
option.
Operation data
Item Description
OPX-2A screen
display
Reference
Tension command Sets the tension command. The rated torque corresponds to
100%.
tEn
p.107
p.111
Material thickness
12
Sets the thickness of material. dt
Initial diameter
12
Sets the initial diameter when winding or unwinding. din
Final diameter
12
Sets the final diameter when winding or unwinding. dPk
p.113
Taper setting
12
This function prevents excessively tight winding. As the roll
diameter increases, the tension is lowered. The tension becomes
constant when the taper setting is 100%.
tEP p.114
Core inertial moment
2
Sets the inertial moment of the core. Jc
Material inertial moment
2
Sets the inertial moment of the material at the maximum material
thickness.
JL
p.114
Speed limit Sets the speed limit value. rEv p.120
∗1 This parameter is set in high function mode I.
∗2 This parameter is set in high function mode II.
Application parameters
Item Description
OPX-2A screen
display
Reference
Output signal selection 1 Selects the output signal. [APP-1-02]
Output signal selection 2 Selects the output signal. [APP-1-03]
Zero speed output band Sets the output condition for ZV output. [APP-1-06] p.119
Minimum ON time for
MOVE signal
Sets the minimum ON time for MOVE output.
[APP-1-08] p.118
Alarm code output Changes the setting to enable/disable alarm code output. [APP-1-10] p.126
Analog speed limit gain Sets the speed limit per 1 V of analog input voltage. [APP-2-00]
Analog speed limit clamp Sets the speed at which to clamp the analog speed limit to zero. [APP-2-01]
Analog speed limit offset
voltage
Sets the offset voltage for analog speed limit input.
[APP-2-02]
p.121
Analog tension command
gain
Sets the tension command per 1 V of analog input voltage.
[APP-2-04]
Analog tension command
offset voltage
Sets the offset voltage for analog tension command input.
[APP-2-05]
Analog input signal
automatic offset
Changes the setting to enable/disable automatic offset for analog
input signals.
[APP-2-06]
p.107
p.111
Analog speed monitor
maximum value
Sets the maximum value of monitored analog speed. This setting
determines the slope of output of monitored analog speed.
[APP-2-07]
Analog speed monitor
maximum voltage
Sets the monitored output voltage corresponding to the
maximum value of monitored analog speed.
[APP-2-08]
Analog speed monitor
offset voltage
Sets the offset voltage for monitored analog speed.
[APP-2-09]
p.124