User manual
12 Functions and operations in the tension control mode
−104−
12.2 List of setting items
The items that can be set in the tension control mode are listed below.
You can use the data setter OPX-2A or the
data setting software MEXE02 to set
operation data or change the internal
parameters of the driver.
Parameter codes displayed on the OPX-2A
screen are shown in brackets. These codes are
also referenced in the main text herein. Use
these codes as keywords.
OPX-2A
MEXE02
For the method to set parameters with the OPX-2A or MEXE02, refer to the operating manual for each
option.
Operation data
Item Description
OPX-2A screen
display
Reference
Tension command Sets the tension command. The rated torque corresponds to
100%.
tEn
p.107
p.111
Material thickness
∗1∗2
Sets the thickness of material. dt
Initial diameter
∗1∗2
Sets the initial diameter when winding or unwinding. din
Final diameter
∗1∗2
Sets the final diameter when winding or unwinding. dPk
p.113
Taper setting
∗1∗2
This function prevents excessively tight winding. As the roll
diameter increases, the tension is lowered. The tension becomes
constant when the taper setting is 100%.
tEP p.114
Core inertial moment
∗2
Sets the inertial moment of the core. Jc
Material inertial moment
∗2
Sets the inertial moment of the material at the maximum material
thickness.
JL
p.114
Speed limit Sets the speed limit value. rEv p.120
∗1 This parameter is set in high function mode I.
∗2 This parameter is set in high function mode II.
Application parameters
Item Description
OPX-2A screen
display
Reference
Output signal selection 1 Selects the output signal. [APP-1-02]
Output signal selection 2 Selects the output signal. [APP-1-03]
−
Zero speed output band Sets the output condition for ZV output. [APP-1-06] p.119
Minimum ON time for
MOVE signal
Sets the minimum ON time for MOVE output.
[APP-1-08] p.118
Alarm code output Changes the setting to enable/disable alarm code output. [APP-1-10] p.126
Analog speed limit gain Sets the speed limit per 1 V of analog input voltage. [APP-2-00]
Analog speed limit clamp Sets the speed at which to clamp the analog speed limit to zero. [APP-2-01]
Analog speed limit offset
voltage
Sets the offset voltage for analog speed limit input.
[APP-2-02]
p.121
Analog tension command
gain
Sets the tension command per 1 V of analog input voltage.
[APP-2-04]
Analog tension command
offset voltage
Sets the offset voltage for analog tension command input.
[APP-2-05]
Analog input signal
automatic offset
Changes the setting to enable/disable automatic offset for analog
input signals.
[APP-2-06]
p.107
p.111
Analog speed monitor
maximum value
Sets the maximum value of monitored analog speed. This setting
determines the slope of output of monitored analog speed.
[APP-2-07]
Analog speed monitor
maximum voltage
Sets the monitored output voltage corresponding to the
maximum value of monitored analog speed.
[APP-2-08]
Analog speed monitor
offset voltage
Sets the offset voltage for monitored analog speed.
[APP-2-09]
p.124