User manual
4 Introduction
−11−
• For Low Voltage Directive
• The product is a type with machinery incorporated, so it should be installed within an enclosure.
• This product cannot be used with cables normally used for IT equipment.
• Install the product within the enclosure in order to avoid contact with hands.
• Be sure to maintain a protective ground in case hands should make contact with the product.
Be sure to connect the protective earth lead of the cable for motor to the protective earth terminal on the
driver, and ground the driver’s protective earth terminal.
• To protect against electric shock using an earth leakage breaker (RCD), connect a type B earth leakage
breaker to the primary side of the driver.
• When using a circuit breaker (MCCB), use a unit conforming to the EN or IEC standard.
• Isolate the motor cable, power-supply cable and other drive cables from the signal cables (CN1, CN4 to
CN7) by means of double insulation.
• EMC Directive
EMC of this product has been measured according to the configuration illustrated in “Example of installation
and wiring” on p.28. The compliance of the final machinery with the EMC Directive will depend on such
factors as the configuration, wiring, layout and risk involved in the control-system equipment and electrical
parts. It therefore must be verified through EMC measures by the customer of the machinery.
Applicable standards
EMI Emission Tests
Radiated Emission Test
Conducted Emission Test
Harmonics Current Test
Voltage Fluctuations Test
EN 61000-6-4, EN 61800-3 C3
EN 55011 group 1 class A
EN 55011 group 1 class A
EN 61000-3-2
EN 61000-3-3
EMS Immunity Tests
Radiation Field Immunity Test
Electrostatic Discharge Immunity Test
Fast Transient / Burst Immunity Test
Conductive Noise Immunity Test
Surge Immunity Test
Voltage Dip Immunity Test
Voltage Interruption Immunity Test
EN 61000-6-2, EN 61800-3 C3
IEC 61000-4-3
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-6
IEC 61000-4-5
IEC 61000-4-11
IEC 61000-4-11
WARNING FOR UL MARKING ON DRIVER
Solid state motor overload protection is provided in each model.
Hazardous substances
RoHS (Directive 2002/95/EC 27Jan.2003) compliant