User manual
13 Monitor functions
−125−
Analog torque monitor
Set the analog torque monitor using the following application parameters:
• Analog torque monitor maximum value [APP-2-10]
Sets the maximum value of detected torque to be monitored.
• Analog torque monitor maximum voltage [APP-2-11]
Sets the voltage at which to detect the maximum torque.
• Analog torque monitor offset voltage [APP-2-12]
This parameter is set when the home position of output voltage is to be offset.
Setting
example
Analog torque
monitor maximum
value [APP-2-10]
Analog torque monitor
maximum voltage
[APP-2-11]
Analog torque
monitor offset
voltage [APP-2-12]
Description
① 300% 10 V 0 V
When the detected torque is 300%, 10 V
is output.
② 150% 3 V 0 V
When the detected torque is 150%, 3 V is
output. The voltage does not rise above
3 V even when the detected torque
exceeds 150%.
③ 150% 10 V 0 V
When the detected torque is 150%, 10 V
is output.
④ 300% 10 V 1 V
The home position of output voltage
becomes 1 V.
Output voltage [V]
10
3
-
150
-
300
150
300
-
3
-
10
1
4
3
2
Detected torque [%]
Note
Even when a torque above the maximum voltage is detected, the output will not exceed
the maximum voltage.