Alarm reset
Perform one of the reset operations specified below.
Before resetting an alarm, always remove the cause of the alarm and ensure safety.
Turn the ALM-RST input to ON and then OFF. (The alarm will be reset at the OFF edge of the input.)
Perform an alarm reset using the OPX-2A or MEXE02.
Cycle the power.
Note
Some alarms cannot be reset with the ALM-RST input or alarm reset functions provided
by the OPX-2A and MEXE02. Check which alarms fall under this category in the tables
provided on the following pages. To reset these alarms, the power must be cycled. If a
24 VDC power supply is connected, also cycle the 24 VDC power supply.
The absolute position loss alarm cannot be reset with the ALM-RST input alone. Refer
to p.63 for details on the method to reset this alarm.
Characteristics of the overload alarm
How long it takes to detect an overload alarm varies depending on the torque.
Reference overload detection time
Continuous
output torque
Overload detection time
100% Continuous
125% Approx. 10 sec
150% Approx. 4 sec
250% Approx. 1 sec
300% Approx. 0.5 sec
Overload detection time (reference)
0
1
2
3
4
5
6
7
8
9
10
11
100 150 200 250 300
Load factor (%)
Overload detection time (sec)
The load factor is 100% when the rated torque is output.