User manual
17 General specifications
−137−
Note
If the ambient temperature of the driver exceeds 40 °C (104 °F) while the driver is in use,
keep the continuous output of the motor to or below the derating curve shown below. For
your information, there is no need for derating for the models whose rated output is 50 W
or 400 W.
Derating curve for continuous motor output
Rated output: 100 W
20
40
60
80
100
0 1020304050
Ambient temperature [°C]
Continuous motor output [W]
Derating curve for continuous motor output
Rated output: 200 W
0
25
50
75
100
125
150
175
200
10 20 30 40 50
Ambient temperature [°C]
Continuous motor output [W]
150
300
450
600
750
0 1020304050
Derating curve for continuous motor output
Rated output: 750 W
Ambient temperature [°C]
Continuous motor output [W]
Battery specifications
Battery type Lithium thionyl chloride batteries
Life Approx. 4 years
∗
Data retention period 2 years
∗
Ambient temperature 0 to +50 °C (+32 to +122 °F) (non-freezing)
Ambient humidity 85% or below (non-condensing)
Storage/Transporting temperature +5 to +35 °C (+41 to +95 °F) (non-freezing)
Storage/Transporting humidity 70% or below (non-condensing)
∗ At an ambient temperature of 20 °C (68 °F)